Integrate Revolution Pi into an industrial network
It is not easy at all to integrate a device into an industrial network. Special protocols are often used for data transmission, such as Profinet or Profibus. When
using our gateways – called RevPi Gate – integrating Revolution Pi into an industrial network is however no problem. Like all Revolution Pi expansion modules, the gateways are also connected to the base module RevPi Core via the overhead Pi Bridge connector. Thus, up to two gateway modules can be used per system. The cyclic data exchange between gateway and the central process image of the RevPi Core 3 takes place every 5 ms, regardless of the bus protocol and system configuration. Due to the required processing power, we recommend the use of gateways exclusively in conjunction with the Quad-Core equipped RevPi Core 3. We offer gateways for the following network protocols: All module variants have been tested and certified at the respective user organisations:
Protocol | PROFINET IRT |
Master/Slave | Slave |
Bus connector | 2 x RJ45 |
Max. baud rate | 100 Mbit/s |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100074 |
Protocol | EtherNet/IP |
Master/Slave | Slave |
Bus connector | 2 x RJ45 |
Max. baud rate | 100 Mbit/s |
I/O Data | 480 Bytes IN/OUT |
Item no. | 100066 |
Protocol | POWERLINK |
Master/Slave | Slave |
Bus connector | 2 x RJ45 |
Max. baud rate | 100 Mbit/s |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100076 |
Protocol | EtherCAT |
Master/Slave | Slave |
Bus connector | 2 x RJ45 |
Max. baud rate | 100 Mbit/s |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100073 |
Protocol | Sercos III |
Master/Slave | Slave |
Bus connector | 2 x RJ45 |
Max. baud rate | 100 Mbit/s |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100075 |
Protocol | Modbus TCP |
Master/Slave | Slave |
Bus connector | 2 x RJ45 |
Max. baud rate | 10/100 Mbit/s |
I/O Data | 480 Bytes IN/OUT |
Item no. | 100088 |
Protocol | PROFIBUS |
Master/Slave | Slave |
Bus connector | D-SUB 9F |
Max. baud rate | up to 12 Mbit/s |
I/O Data | 244 Bytes IN/OUT |
Item no. | 100069 |
Protocol | DeviceNet |
Master/Slave | Slave |
Bus connector | 5 pole / pitch 5.08 |
Max. baud rate | up to 500 Kbit/s |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100071 |
Protocol | CANopen |
Master/Slave | Slave |
Bus connector | D-SUB 9M |
Max. baud rate | up to 1 Mbit/s |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100070 |
Protocol | Modbus RTU |
Master/Slave | Slave |
Bus connector | 8 pole / pitch 3.50 |
Max. baud rate | up to 115.2 Kbit/s |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100090 |
Protocol | Serial |
Master/Slave | Slave |
Bus connector | 8 pole / pitch 3.50 |
Max. baud rate | up to 115.2 Kbit/s |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100068 |
Protocol | DMX |
Master/Slave | Master/Slave |
Bus connector | 8 pole / pitch 3.50 |
Max. baud rate | – |
I/O Data | 512 Bytes IN/OUT |
Item no. | 100237 |